A,features
1. The use of normally open or normally closed sensors, accurate, the median and the transformation of direct monitoring of the valve core position;
2. The sensor specifications provide PNP and NPN two choices;
3. Fast response time, high safety coefficient, long life;
4. Compact structure, small, convenient installation and wiring.
5. "AB" sensor location is suitable for double electromagnets, can also be applied to single head electromagnet;
Second,Model specification
SWH-G03 -B2-D24-20-PMBD24NO
1 2 3 4 5 6 7 8 9 10
1: electromagnetic directional valve
2: installation G: plate installation
3:02: nominal diameter NG6 (CETOP3 D03);03: NG10 (CETOP5 D05)
4: sliding column type As shown in the column type table
D24:5: coil voltage 24 v DC
6: solenoid valve connection mode: 20 plug-in socket with indicator light (PG11)
7: PM sensor specifications: PNP specifications;PH: NPN specification
8: sensor monitoring location B: B coil actuation, the reversing valve core in place;A: detecting A moving coil, reversing valve core in place
9: sensor voltage D24: DC 24 v
10: NO sensor contact way: normally open (standard);NC: normally closed (products)
SW -G04 -C2-ET -D24-20-PMBD24NO
1 2 3 4 5 6 7 8 9 10 11 12
1: electro-hydraulic directional control valve
2: installation G: plate installation
4:3: nominal size NG16 (CETOP7 D07);06: NG20 (CETOP8 D08)
4: sliding column type As shown in the column type table
5: control mode E: external control;Blank: internal control (standard)
6: drainage way T: leak;Blank: drainage (standard)
D24:7: coil voltage 24 v DC
8: solenoid valve connection mode: 20 plug-in socket with indicator light (PG11)
9: PM sensor specifications: PNP specifications;PH: NPN specification
10: sensor monitoring location B: B coil actuation, the reversing valve core in place;A: detecting A moving coil, reversing valve core in place
AB: detection on both sides of the reversing valve core in place;O: neutral testing valve core reset
11: sensor voltage D24: DC 24 v
12: NO sensor contact way: normally open (standard);NC: normally closed (products)
Sliding column type table
SWH-G02/G03
SW-G04/G06
Note: other sliding column type, please contact our technical department;
Three, specification table
Type no. | Maximum flow rate (l/min) | The highest working pressure (bar) | Maximum permissible back pressure (bar) | Reversing highest frequency (back/min) |
SWH-G02-** | 63 | 315 | 160 | 300 |
SWH-G03-** | 120 | |||
SW-G04-** | 300 | |||
SW-G06-** | 500 |